Insulated Electric Wire


Drop Wire for Pole Transformer(PDC, PDE)
22.9kV High Voltage Drop Insulated Wire for XLPE (PDC, PDE)
Range of application
Power cable used on the primary aspect of the pole transformer of high voltage overhead power line

Constitution

  • Conductor : Hard-drawn copper wire or annealed copper wire for electrical application
  • Semi-conductive layer : Semi-conductive XLPE
  • Insulator : XLPE, PE
  • Color of the insulator : Black
  • Sheath:Black (Only for PDE)
  • Product certifications : Standards of Hanmi

 

Conductor Insulation
Thickness
Approx.
Overall
Diameter
Conductor
Resistance
at 20℃
Test
Voltage
Standard
Length
Sectional
Area
No & Diameter
of wire
Outer
Diameter
mm2 No/mm mm mm Ω/km kV m
-
-
-
-
5.5
8
14
22
30
2.0
2.6
3.2
5.0
7/1.0
7/1.2
7/1.6
7/2.0
7/2.3
2.0
2.6
3.2
5.0
3.0
3.6
4.8
6.0
6.9
3.0
3.0
3.0
4.0
3.0
3.0
3.0
3.0
3.0
8.0
8.6
9.2
13.0
9.0
9.6
11.0
12.0
13.0
5.7
3.35
2.21
0.905
3.33
2.31
1.30
0.824
0.623
12
12
12
12
12
12
12
12
12
300
300
300
300
300
300
300
300
300
PDC
5.5 7/1.0 3.0 4.0 14.6 3.33 12 300 PDE


60227 KS IEC 07
Single stranded vinyl insulation electric wire for 300/500V device wiring: 90℃
Range of application
It is a thermal resistant plasticizer added PVC insulated electric wire used mostly for general electric products or devices that use voltage of 300/500V.

Constitution

  • Conductor : 1 grade (single-stranded) insulator
  • Insulation material : PVC/E
  • Color of the insulator : Black, white, red, green, yellow and blue
  • Applicable specifications : KS C IEC60227-3
  • Product certifications : Korean Industrial Standard(KS)

KS C IEC60227-3

Conductor Insulation
Thickness
Mean Overall Diameter Insulation
Resistance
Standard
Length
Test
Voltage
Approx.
Weight
Nominal Area Class Lower Limit Upper Limit
mm2 - mm mm mm MΩ·km m kV kg/km
1.5
2.5
1
1
0.7
0.8
2.6
3.2
3.2
3.9
12.1
7.41
0.011
0.009
2.5
2.5
20
40


60227 KS IEC 01
General use single-stranded vinyl insulated electric wire for 450/750V
Range of application
It is an insulated electric wire used mostly for external wiring with voltage of 450/750V and is characterized by good weather-resistance and durability.

Constitution

  • Conductor : Grade 1 (single-strand) or grade 2 (multiple-strand) conductor
  • Insulation material : PVC/C
  • Color of the insulator : Black, white, red, green, yellow and blue
  • Applicable specifications : KS C IEC60227-3
  • Product certifications : Korean Industrial Standard(KS)

KS C IEC60227-3

Conductor Insulation
Thickness
Mean Overall Diameter Insulation
Resistance
Standard
Length
Test
Voltage
Approx.
Weight
Nominal Area Class Lower Limit Upper Limit
mm2 - mm mm mm MΩ·km m kV kg/km
1.5
2.5
4.0
6.0
10
1
1
1
1
1
0.7
0.8
0.8
0.8
1.0
2.6
3.2
3.6
4.1
5.3
3.2
3.9
4.4
5.0
6.4
12.1
7.41
4.61
3.08
1.83
0.011
0.009
0.0085
0.0070
0.0070
2.5
2.5
2.5
2.5
2.5
20
40
50
70
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.4
2.6
2.7
3.3
3.8
4.3
5.6
6.4
8.1
9.0
10.6
12.1
14.1
15.6
17.3
19.3
22.3
24.5
27.5
3.3
4.0
4.6
5.2
6.7
7.8
9.7
10.9
12.8
14.6
17.1
18.8
20.9
23.3
26.6
29.6
33.2
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.010
0.009
0.0077
0.0065
0.0065
0.0050
0.0050
0.0043
0.0043
0.0035
0.0035
0.0032
0.0032
0.0032
0.0032
0.0030
0.0028
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
20
40
50
70
120
170
260
350
480
670
920
1160
1430
1780
2320
2930
3730


450/750 HFIX
450/750V 저독성 가교 폴리올레핀 절연전선
Range of application
It is halogen free polyolefin insulated electric wire used mainly as conductor for outdoor wiring for voltages below 450/750V with maximum allowed temperature of 90℃ for application.

Constitution

  • Conductor : Grade 1 (single-strand) or grade 2 (multiple-strand) conductor
  • Insulation material : Halogen free polyolefin
  • Color of the insulator : Black, white, red, green, yellow and blue
  • Applicable specifications : KS C 3341
  • Product certifications : Korean Industrial Standard(KS)

KS C 3341

Conductor Insulation
Thickness
Mean Overall Diameter Insulation
Resistance
Standard
Length
Test
Voltage
Approx.
Weight
Nominal Area Class Lower Limit Upper Limit
mm2 - mm mm mm MΩ·km m kV kg/km
1.5
2.5
4
6
10
1
1
1
1
1
0.7
0.8
0.8
0.8
1.0
2.6
3.2
3.6
4.1
5.3
3.2
3.9
4.4
5.0
6.4
12.1
7.41
4.61
3.08
1.83
0.011
0.009
0.0085
0.0070
0.0070
2.5
2.5
2.5
2.5
2.5
20
40
50
70
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.0
2.4
2.6
2.7
3.3
3.8
4.3
5.6
6.4
8.1
9.0
10.6
12.1
14.1
15.6
17.3
19.3
22.3
24.5
27.5
3.3
4.0
4.6
5.2
6.7
7.8
9.7
10.9
12.8
14.6
17.1
18.8
20.9
23.3
26.6
29.6
33.2
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.010
0.009
0.0077
0.0065
0.0065
0.0050
0.0050
0.0043
0.0043
0.0035
0.0035
0.0032
0.0032
0.0032
0.0032
0.0030
0.0028
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
20
40
50
70
120
170
260
350
480
670
920
1160
1430
1780
2320
2930
3730


KIV450/750V PVC Insulated wire for Electrical Apparatus
Flexible single-stranded vinyl insulated electric wire for general application for voltage range of 450/750V (450/750V KIV)
Range of application
It is a flexible insulated electric wire used mainly for electrical devices that use voltage in the range of 450/750V.

Constitution

  • Conductor : Grade 5 (collective and composite multiple-strand)conductor
  • Insulation material : PVC/C
  • Color of the insulator : Black, white, red, green, yellow and blue
  • Applicable specifications : KS C IEC 60227-3
  • Product certifications : Korean Industrial Standard(KS)

KS C IEC 60227-3

Conductor Insulation
Thickness
Mean Overall Diameter Plain Tinned Insulation
Resistance
Approx.
Weight
Standard
Length
Nominal Area Class Lower Limit Upper Limit
mm2 - mm mm mm Ω/km Ω/km MΩ·km kg/km km
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.8
3.4
3.9
4.4
5.7
6.7
8.4
9.7
11.5
13.2
15.1
16.7
18.6
20.6
23.5
3.4
4.1
4.8
5.3
6.8
8.1
10.2
11.7
13.9
16.0
18.2
20.2
22.5
24.9
28.4
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
 13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
0.010
0.009
0.007
0.006
0.0056
0.0046
0.0044
0.0038
0.0037
0.0032
0.0032
0.0029
0.0029
0.0029
0.0028
30
40
50
80
130
180
280
370
500
700
970
1200
1490
1850
2440
200
200
100
100
100
100
100
100
100
100
100
100
100
100
100


OWOutdoor Weather Proof PVC Insulated Wire
600V outdoor vinyl insulated electric wire
Range of application
It is used for low-voltage overhead power line. This insulated electric wire with hard-drawn cable as conductor sheathed with PVC has outstanding weather resistance and durability.

Constitution

  • Conductor : Hard-drawn cable, hard-drawn multiple-strand cable for electrical application
  • Insulation material : PVC
  • Color of the insulator : Black
  • Applicable specifications : KS C 3313
  • Product certifications : Korean Industrial Standard(KS)

Single-strand conductor (Solid Conductor)

Conductor Insulation
Thickness
Approx.
Overall
Diameter
Conductor
Resistance
Test
Voltage
Tensile
Load
Approx.
Weight
Standard
Length
Diameter Sectional
Area
mm2 mm2 mm mm Ω/km V/1min kg kg/km km
2.0
2.6
3.2
4.0
5.0
3.142
5.309
8.042
12.57
19.64
0.4
0.5
0.6
1.0
1.0
2.8
3.6
4.4
6.0
7.4
5.83
3.45
2.28
1.46
0.932
3,000
3,000
3,000
3,000
3,000
134.0
223.2
333.0
499.1
759.8
32
54
81
135
210
300
300
200
200
200

Multiple-strand conductor (Stranded Conductor)

Conductor PVC
Insulation
Thickness
Approx.
Overall
Diameter
Conductor
Resistance
at 20℃
Test
Voltage
Tensile
Load
Approx.
Weight
Standard
Length
Sectional
Area
No/mm
No & Diameter
of wire
Outer
Diameter
mm2 No/mm mm mm Ω/km V/1min kg kg/km km
8
14
22
30
38
50
60
80
100
7/1.2
7/1.6
7/2.0
7/2.3
7/2.6
19/1.8
19/2.0
19/2.3
19/2.6
3.6
4.8
6.0
6.9
7.8
9.0
10.0
11.5
13.0
0.6
1.0
1.2
1.2
1.4
1.4
1.4
1.5
1.5
4.8
6.8
8.4
9.3
11.0
12.0
13.0
14.5
16.0
2.41
1.35
0.849
0.642
0.502
0.394
0.313
0.237
0.185
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
326
574
889
1,160
1,480
1,960
2,410
3,160
4,010
90
160
250
320
410
520
630
820
1,030
300
300
300
300
300
300
300
300
300


DVPVC Insulated Drop Wire
600V vinyl insulated electric drop wire
Range of application
It is generally used for overhead service line with voltage of less than 600V. With distinct coloring of each of the strands, it is convenient at the time of wiring with highly outstanding weather resistance of the sheathing. Therefore, it can be used safely for prolonged period of time wire fire or electrocution accident.

Constitution

  • Conductor : Hard-drawn cable for electrical application
  • Insulation material : PVC
  • Identification of cable strand : Coloring (2 Strands: Black and green / 3 Strands: Black, green and blue)
  • Applicable specifications : KS C 3315
  • Product certifications : Korean Industrial Standard (KS)

2-stranded Duplex (DV-2R)

Conductor PVC
Insulation
Thickness
Approx.
Outer
Diameter
Conductor
Resistance
at 20℃
Test voltage Min.
Insulation
Resistance
MW·km
Tensile
Load
Allowed current Approx.
Weight
Standard
Length
Sectional
Area
No/mm
No & Diameter
of wire
Outer
Diameter
mm2 No/mm mm mm mm W/km Between conductor
(in air)
Between conductor
(in water)
20℃ 60℃ kgf A kg/km m
-
-
-
8
14
22
*30
38
*50
2.0
2.6
3.2
7/1.2
7/1.6
7/2.0
7/2.3
7/2.6
19/1.8
2.0
2.6
3.2
3.6
4.8
6.0
6.9
7.8
9.0
0.8
1.0
1.2
1.2
1.4
1.6
1.6
1.8
1.8
7.2
9.2
11.5
12.0
15.5
18.5
21.0
23.0
26.0
5.89
3.48
2.30
2.46
1.38
0.832
0.623
0.492
0.382
3000
3000
3000
3000
3000
4000
4000
4000
4000
1500
1500
1500
1500
2000
2000
2000
2500
2500
50
50
50
50
40
40
40
40
30
0.15
0.15
0.15
0.15
0.1
0.1
0.1
0.1
0.1
127
211
316
326
574
418
570
722
900
28
38
40
49
70
92
111
130
152
75
125
190
205
340
525
680
860
1100
300
200
200
300
300
300
300
300
300

3-stranded Duplex (DV-3R)

Conductor PVC
Insulation
Thickness
Approx.
Outer
Diameter
Conductor
Resistance
at 20℃
Test voltage Min.
Insulation
Resistance
MW·km
Tensile
Load
Allowed current Approx.
Weight
Standard
Length
Sectional
Area
No/mm
No & Diameter
of wire
Outer
Diameter
mm2 No/mm mm mm mm W/km Between conductor
(in air)
Between conductor
(in water)
20℃ 60℃ kgf A kg/km m
-
-
-
8
14
22
*30
38
*50
2.0
2.6
3.2
7/1.2
7/1.6
7/2.0
7/2.3
7/2.6
19/1.8
2.0
2.6
3.2
3.6
4.8
6.0
6.9
7.8
9.0
0.8
1.0
1.2
1.2
1.4
1.6
1.6
1.8
1.8
7.8
9.9
12.5
13.0
16.5
20.0
22.0
25.0
28.0
5.89
3.48
2.30
2.46
1.38
0.832
0.629
0.492
0.382
3000
3000
3000
3000
3000
4000
4000
4000
4000
1500
1500
1500
1500
2000
2000
2000
2500
2500
55
55
55
55
45
45
45
45
35
0.2
0.2
0.2
0.2
0.15
0.15
0.15
0.15
0.15
127
211
316
326
574
418
570
722
900
25
34
44
43
62
62
97
113
133
115
190
285
310
510
785
1025
1290
1650
300
200
200
300
300
300
300
300
300