Aluminum Electric Wire
ACSR Aluminum Stranded Conductors Steel Reinforced Wire
Steel Reinforced Aluminum Stranded Conductor Wire
Range of application
To be used for overhead power lines
To be used for overhead power lines
Constitution
- Conductor: Hard-drawn aluminum electric wire and zinc plated steel wire
- Applicable specifications: KS C 3113, ES6145-0005, ES6145-0020, ES6145-0023
- Product certifications: Korean Industrial Standard(KS), Specifications of KEPCO
Aluminum Stranded Conductors Steel Reinforced Wire (ACSR)
Nominal Sectional Area | No. & Diameter of Wire | Overall Outer Diameter of Completed Product (approximate) |
Tensile Road |
Current carrying Capacity A |
Weight | Conductor Resistace at 20℃ |
Standard Length |
|||
---|---|---|---|---|---|---|---|---|---|---|
Al | St | |||||||||
mm2 | No/mm | mm2 | mm | kgf | 40℃ | 30℃ | 20℃ | kg/km | Ωkm | m |
19 32 58 |
6/2.0 6/2.6 6/3.5 |
1/2.0 1/2.6 1/3.5 |
6.0 7.8 10.5 |
698 1,140 1,980 |
112 155 222 |
124 172 248 |
135 188 271 |
76.12 128.6 233.1 |
1.52 0.899 0.497 |
1000 1000 1000 |
*65 80 95 *97 |
12/2.6 6/4.2 6/4.5 12/3.2 |
7/2.6 1/4.2 1/4.5 7/3.2 |
13.0 12.6 13.5 16.0 |
5,415 2,770 3,180 10,600 |
- - 296 310 |
- - 308 348 |
- - 362 381 |
465.0 335.5 385.2 708.9 |
0.4565 0.345 0.301 0.301 |
1000 1000 1300 1300 |
*120 120 160 200 240 |
12/3.2 30/2.3 30/2.6 30/2.9 30/3.2 |
7/3.5 7/2.3 7/2.6 7/2.9 7/3.2 |
17.5 16.1 18.2 20.3 22.4 |
9,590 5,550 6,990 8,620 10,210 |
355 355 410 473 536 |
398 398 461 532 603 |
436 436 505 583 662 |
845.9 573.9 732.8 911.7 1,110 |
0.25 0.233 0.182 0.147 0.12 |
1300 1300 1300 1400 1400 |
330 410 *480 520 610 |
26/4.0 26/4.5 45/3.7 54/3.5 54/3.8 |
7/3.1 7/3.5 7/2.47 7/3.5 7/3.8 |
26.3 28.5 29.61 31.5 34.2 |
10,930 13,890 11,800 15,600 18,150 |
643 749 807 851 947 |
825 845 910 960 1070 |
796 929 1001 1057 1177 |
1,320 1,673 1,599 1,969 2,320 |
0.0888 0.0702 0.05994 0.0559 0.0474 |
1000 1000 1000 1000 1000 |
※It is the specification of KEPCO.
Steel Reinforced Aluminum Stranded Conductor Wire (Cardinal)
Nominal Sectional Area |
Composition of Strands | Calculated Section Area (mm2) |
Min Tensile Load |
Weight | Max.Conductor Resistace at 20℃ |
Over allDiameter (mm) |
Length | |||
---|---|---|---|---|---|---|---|---|---|---|
Al | St | |||||||||
mm2 | No/mm | No/mm | Al | St | kgf | kg/km | Ω/km | Al | St | m |
480 Cardinal |
54/3.38 | 7/3.38 | 484.53 | 62.81 | 15,300 | 1,836 | 0.0599 | 30.42 | 10.14 | 1,0002,000 |
Steel Reinforced Aluminum Stranded Conductor Wire with Aluminum Sheathing (ACSR/AW)
Nominal Sectional Area |
No. & Dia. of Wire No/mm |
Min Tensile Road |
(AL) Overall Diameter |
Current carrying Capacity | Weight | Electric Resistace |
Standard Length |
|||
---|---|---|---|---|---|---|---|---|---|---|
mm2 | Al | St | kgf | mm | 40℃ | 30℃ | 20℃ | kg/km | Ωkm | m |
32 58 65 95 97 |
6/2.6 6/3.5 12/2.6 6/4.5 12/3.2 |
1/2.6 1/3.5 7/2.6 1/4.5 7/3.2 |
1,140 1,980 5,415 3,180 10,600 |
7.8 10.5 13.0 13.5 16.0 |
159 228 242 304 313 |
177 255 271 340 351 |
193 278 296 372 385 |
120.6 299.7 401 362 608 |
0.852 0.471 0.380 0.285 0.295 |
1,000 1,000 1,000 1,000 1,000 |
120 160 240 330 410 |
12/3.5 30/2.6 30/3.2 26/4.0 26/4.5 |
7/3.5 7/2.6 7/3.2 7/3.1 7/3.5 |
9,590 6,990 10,210 10,930 13,890 |
17.5 18.2 22.4 25.3 28.5 |
382 426 558 661 770 |
429 478 627 744 868 |
470 524 689 817 954 |
737 676.4 1024 1239 1578 |
0.210 0.169 0.111 0.0842 0.0665 |
1,000 1,000 1,000 1,000 1,000 |
480 520 |
45/3.7 54/3.5 |
7/2.47 7/3.5 |
11,800 15,600 |
29.61 31.5 |
816 869 |
921 981 |
1012 1079 |
1544 1848 |
0.0586 0.0536 |
1,000 1,000 |
ACSR/AW-OC ACSR/AW Outdoor XLPE Insulated wire
Insulated aluminum wire with aluminum sheathed steel core
Range of application
For application on high-voltage overhead power lines
For application on high-voltage overhead power lines
Constitution
- Conductor : Hard-drawn aluminum line for electrical application, aluminum wire with steel core, stranded aluminum wire with aluminum sheathed steel core
- Insulation material : XLPE
- Color of the insulator : Black
- Applicable specifications : ES 6145-0006~8
- Product certifications : KEPCO Certification
Insulated aluminum wire with aluminum sheathed steel core (ACSR/AW-OC)
Voltage | Nominal Sectional Area |
No. & Dia. of Wire (Al) |
No. & Dia. of Wire (St) |
Outer Diameter |
Insulation Thickness |
Overall Diameter |
Max. Conductor Resistance at 20℃ |
Test Voltage |
Min. Insulation Resistance at 20℃ |
Conductor Min. Tensile Road |
Weight | Standard Length |
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm2 | mm2 | No/mm | No/mm | mm | mm | mm | Ω/km | kV | MΩ/km | kgf | kg/km | m |
6.6kV | 32 58 95 |
6/SB 6/SB 6/SB |
1/2.6 1/3.5 1/3.5 |
7.2 9.7 12.0 |
2.0 2.5 2.5 |
11.2 14.7 17.0 |
0.877 0.484 0.302 |
12 12 12 |
1,500 1,500 1,500 |
1,090 1,900 2,360 |
180 315 445 |
900 600 300 |
22.9kV | 32 58 95 160 |
6/SB 6/SB 6/SB 18/SB |
1/2.6 1/3.5 1/3.5 1/3.2 |
7.2 9.7 12.0 15.4 |
3.0 3.0 3.5 4.0 |
13.2 15.7 19.0 23.4 |
0.877 0.484 0.302 0.183 |
25 25 25 25 |
2,000 1,500 1,500 1,500 |
1,090 1,900 2,360 3,080 |
210 330 530 730 |
900 600 600 600 |
(Special) Insulated high-voltage aluminum electric wire with steel core (ACSR-OC)
Voltage | Nominal Sectional Area |
Conductor | Outer Diameter |
Insulation Thickness |
Overall Diameter |
Max. Conductor Resistance at 20℃ |
Test Voltage |
Min. Insulation Resistance at 20℃ |
Conductor Min. Tensile Road |
Weight | Standard Length |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. & Dia. of Wire (Al) |
No. & Dia. of Wire (St) |
|||||||||||
mm2 | mm2 | No/mm | No/mm | mm | mm | mm | Ω/km | kV | MΩ/km | kgf | kg/km | m |
6.6kV | 32 58 95 |
6/SB 6/SB 6/SB |
1/2.6 1/3.5 1/3.5 |
7.2 9.7 12.0 |
2.0 2.5 2.5 |
11.2 14.7 17.0 |
0.928 0.512 0.313 |
12 12 12 |
1,500 1,500 1,500 |
1,090 1,900 2,360 |
185 325 455 |
900 600 300 |
22.9kV | 32 58 95 160 |
6/SB 6/SB 6/SB 18/SB |
1/2.6 1/3.5 1/3.5 1/3.2 |
7.2 9.7 12.0 15.4 |
3.0 3.0 3.5 4.0 |
13.2 15.7 19.0 23.4 |
0.928 0.512 0.313 0.186 |
25 25 25 25 |
2,000 1,500 1,500 1,500 |
1,090 1,900 2,360 3,080 |
215 340 540 740 |
900 600 600 600 |