Bare Copper Cable
AS Annealed Copper Stranded Wire for Electrical Purpose
Range of application
Use for electrical conductor and other applications
Use for electrical conductor and other applications
Constitution
- Conductor : Annealed copper stranded wire for electrical application
- Applicable specifications : KS C 3103
- Product certifications : Korean Industrial Standard(KS)
KSC 3103
Nominal Sectional Area(mm2) | No. & Diameter of Wire (No/mm) | Computed Sectional Area (mm2) | Outer Diameter(mm) | Standard Weight (kg/km) | Electrical Resistance (Ωkm) | Standard Length (m) |
---|---|---|---|---|---|---|
0.9 1.25 1.4 2.0 3.5 |
7/0.4 7/0.45 7/0.5 7/0.6 7/0.8 |
0.8799 1.113 1.375 1.979 3.519 |
1.2 1.35 1.5 1.8 2.4 |
7.91 10.02 12.37 17.80 31.66 |
20.0 15.8 12.7 8.82 4.96 |
500 500 500 500 500 |
5.5 8 14 22 30 |
7/1.0 7/1.2 7/1.6 7/2.0 7/2.3 |
5.498 7.917 14.08 21.99 29.09 |
3.0 3.6 4.8 6.0 6.9 |
49.46 71.19 126.7 197.9 261.7 |
3.17 2.20 1.24 0.793 0.600 |
500 500 500 300 300 |
35 50 70 95 120 |
7/2.52 19/1.78 19/2.14 19/1.78 37/2.03 |
34.91 47.28 68.34 94.76 119.75 |
7.56 8.90 10.70 12.60 14.21 |
313.57 426.62 616.68 854.91 1084.59 |
0.524 0.387 0.268 0.193 0.153 |
300 1000 1000 600 600 |
150 185 240 300 400 |
37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 |
147.11 184.54 242.54 304.24 389.14 |
15.75 17.64 20.25 22.68 25.65 |
1331.92 1671.85 2211.04 2775.72 3549.98 |
0.124 0.0991 0.0754 0.0601 0.0470 |
600 500 300 300 300 |
500 630 800 1000 |
61/3.20 127/2.52 127/2.85 127/3.20 |
490.59 633.42 81.18 1021.39 |
28.80 32.76 37.05 41.60 |
4470.04 5854.30 7481.70 9469.86 |
0.0366 0.0283 0.0221 0.0176 |
300 300 300 300 |
HS Hard Drawn Copper Stranded Wire for Electrical Purpose
Range of application
Use for electrical conductor and other applications
Use for electrical conductor and other applications
Constitution
- Conductor : Hard Drawn Copper Stranded Wire for Electrical Purpose
- Applicable specifications : KS C 3103
- Product certifications : Korean Industrial Standard(KS)
KSC 3103
Nominal Sectional Area (mm2) | No. & Diameter of Wire (No/mm) | Computed Sectional Area (mm2) | Outer Diameter (mm) | Standard Weight (kg/km) | Electrical Resistance (Ωkm) | Standard Length (m) |
---|---|---|---|---|---|---|
0.9 1.25 1.4 2.0 3.5 |
7/0.4 7/0.45 7/0.5 7/0.6 7/0.8 |
0.8799 1.113 1.375 1.979 3.519 |
1.2 1.35 1.5 1.8 2.4 |
7.91 10.02 12.37 17.80 31.66 |
20.0 15.8 12.7 8.82 4.96 |
500 500 500 500 500 |
5.5 8 14 22 30 |
7/1.0 7/1.2 7/1.6 7/2.0 7/2.3 |
5.498 7.917 14.08 21.99 29.09 |
3.0 3.6 4.8 6.0 6.9 |
49.46 71.19 126.7 197.9 261.7 |
3.17 2.20 1.24 0.793 0.600 |
500 500 500 300 300 |
35 50 70 95 120 |
7/2.52 19/1.78 19/2.14 19/1.78 37/2.03 |
34.91 47.28 68.34 94.76 119.75 |
7.56 8.90 10.70 12.60 14.21 |
313.57 426.62 616.68 854.91 1084.59 |
0.524 0.387 0.268 0.193 0.153 |
300 1000 1000 600 600 |
150 185 240 300 400 |
37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 |
147.11 184.54 242.54 304.24 389.14 |
15.75 17.64 20.25 22.68 25.65 |
1331.92 1671.85 2211.04 2775.72 3549.98 |
0.124 0.0991 0.0754 0.0601 0.0470 |
600 500 300 300 300 |
500 630 800 1000 |
61/3.20 127/2.52 127/2.85 127/3.20 |
490.59 633.42 81.18 1021.39 |
28.80 32.76 37.05 41.60 |
4470.04 5854.30 7481.70 9469.86 |
0.0366 0.0283 0.0221 0.0176 |
300 300 300 300 |